Model |
DTM-352,
DTM-332 |
Telescope |
Tube Length |
158mm/6.22 in. |
Magnification |
33x (21x/41x with optional
eyepieces) |
Effective diameter of objective |
45mm/1.77 in. (EDM: 50mm/1.97
in.) |
Field of view |
1°20’ |
Resolving power |
2.5” |
Minimum focusing distance |
1.3m/4.26 ft |
Distance measurement |
Range with Nikon specified prisms |
|
Normal conditions |
(Ordinary haze, visibility
approx. 20km/12.5 miles) |
With reflector sheet
(5 x 5cm) |
5 to 100m (16.4 to 328
ft.) |
With mini prism |
1,000m/3,280 ft. |
With single prism |
2,000m/6,560 ft |
With triple prism |
2,600m/8,530 ft. |
Good conditions |
(No haze, visibility of
over 40km/25 miles) |
With reflector sheet
(5 x 5cm) |
5 to 100m (16.4 to 328
ft.) |
With mini prism |
1,200m/3,930 ft. |
With single prism |
2,300m/7.540 ft. |
With triple prism |
3,000m/9,840 ft. |
Accuracy (Prism/Precise
mode) |
±(3+2ppm x D)mm
±(3+3ppm x D)mm (–20°C to –10°C, +40°C to +50°C |
Measuring interval*1 |
Precise mode |
1.6 sec. (initial 1.6
sec.) |
Normal mode |
1.0 sec. (initial 1.4
sec.) |
Least count |
Precise mode |
1mm/0.002 ft. |
Normal mode |
10mm/0.02 ft. |
Ambient temperature
range*2 |
–20°C to 50°C/–4°F
to +122°F |
Atmospheric correction |
Temperature range |
–40°C to 60°C/–40°F
to +140°F |
Barometric pressure |
400 to 999mmHg/533 to
1,332hPa/15.8 to 39.3 in.Hg |
Prism offset |
–999 to 999 |
Angle measurement |
Reading system |
Photoelectric detection
by incremental encoder |
Horizontal angle |
Diametrical(DTM-352),
Single(DTM-332) |
Vertical angle |
Single |
Minimum increment
(Degree, Gon, MIL6400) |
Degree: 1/5/10”,
Gon: 0.2/1/2mgon, MIL6400: 0.005/0.02/0,05mil |
DIN 18723 accuracy
(horizontal and vertical) |
5”/1.5mgon |
Tilt sensor |
Type |
Dual-axis(DTM-352), Single-axis(DTM-332) |
Method |
Liquid-electric detection |
Compensation range |
±3' |
Setting accuracy |
1" |
Level vial |
Plate level vial |
30"/2mm |
Circular level vial |
10'/2mm |
Optical plummet |
Magnification |
3x |
Focusing range |
0.5m/1.6 ft. to ∞ |
Display |
Graphic LCD (128 x 64
dot)
Both sides(DTM-352), Single side(DTM-332) |
Point memory |
10,000 records |
Dimensions (W x D x H) |
168 x 173 x 335mm/6.6
x 6.8 x 13.2 in. |
Weight (approx.) |
Main unit (with battery) |
5.3kg/11.7 lbs.(DTM-352),
5.2kg/11.5 lbs.(DTM-332) |
Battery |
0.4kg/0.9 lbs |
Carrying case |
2.4kg/5.3 lbs |
On-board Ni-MH battery
BC-65 |
Operation time |
|
Continuous distance/angle
measurement |
Approx. 16 hours*3 |
Distance/angle
measurement every 30 seconds |
Approx. 27 hours |
Angle measurement |
Approx. 30 hours |
Quick charger Q-75U/E |
Approx. 2.0 hours for
full recharge |
Quick charger Q-70C (12V DC cigarette
lighter charger) |
Approx. 2.0 hours (fully
discharged BC-65 requires more than one charge) |