The Pulse Laser Station NPL-302 Series offers three
models the Nikon NPL-362, NPL-352, and NPL-332. The NPL-302 Series
include excellent measurement performance and extreme long battery
life. The instruments also include powerful onboard software that
remains very easy-to-use and easy-to-learn. With the introduction
of a graphical LCD display the menu selections and data entry has
become even simpler, resulting in increased productivity in the
field. The Nikon Pulse Laser Stations are equipped with the unique
coaxial focusing system reflectorless EDM. Otherwise inaccessible
points can now be surveyed reliable and accurate due to Nikon's
unique reflectorless EDM technology. This system focuses the laser
on the object that is to be measured. The focusing of the laser
beam on the object assures greater accuracy, especially when the
measurement beam is oblique to the target surface.
Model |
NPL-362,
NPL-352, NPL-332 |
Telescope |
Tube Length |
153mm/6.02 in. |
Magnification |
26x (16x/32x with optional
eyepieces) |
Effective diameter of objective |
40mm/1.57 in. (EDM: 50mm/1.97
in.) |
Field of view |
1°30' |
Resolving power |
3" |
Minimum focusing distance |
1.6m/5.3 ft. |
Distance measurement |
Reflectorless mode
(white target)*1 |
1.6 to 210m (5.3 to 682
ft.) |
Range with Nikon specified prisms |
|
Normal conditions |
(Ordinary haze, visibility
approx. 20km/12.5 miles) |
With reflector sheet
(5 x 5cm) |
1.6 to 300m (5.3 to 980
ft.) |
With mini prism |
1.6 to 3,000m (5.3 to
9,840 ft.). |
With single prism |
1.6 to 5,000m (5.3 to
16,400 ft.). |
Good conditions |
(No haze, visibility of
over 40km/25 miles) |
With reflector sheet
(5 x 5cm) |
1.6 to 300m (5.3 to 980
ft.) |
With mini prism |
1.6 to 3,000m (5.3 to
9,840 ft.). |
With single prism |
1.6 to 5,000m (5.3 to
16,400 ft.). |
Accuracy (Prism/Precise
mode) |
Accuracy (Reflectorless/Precise
mode) |
±(5+2ppm x D)mm
±(5+3ppm x D)mm (–20°C to –10°C, +40°C to +50°C) |
Measuring interval*2 |
Prism mode |
|
Precise mode |
1.3 sec. (initial 2.0
sec.) |
Normal mode |
0.5 sec. (initial 1.6
sec.) |
Reflectorless mode |
|
Precise mode |
1.6 sec. (initial 2.6
sec.) |
Normal mode |
0.8 sec. (initial 2.0
sec.) |
Least count |
Precise mode |
1mm/0.002 ft. |
Normal mode |
10mm/0.02 ft. |
Ambient temperature range |
–20°C to 50°C/–4°F
to +122°F |
Atmospheric correction |
Temperature range |
–40°C to 60°C/–40°F
to +140°F |
Barometric pressure |
400 to 999mmHg/533 to
1,332hPa/15.8 to 39.3 in.Hg |
Prism offset |
–999 to 999 |
Angle measurement |
Reading system |
Photoelectric detection
by incremental encoder |
Horizontal angle |
Diametrical(NPL-362/352),
Single(NPL-332) |
Vertical angle |
Single |
Minimum increment
(Degree, Gon, MIL6400) |
Degree: 1/5/10”,
Gon: 0.2/1/2mgon, MIL6400: 0.005/0.02/0,05mil |
DIN 18723 accuracy
(horizontal and vertical) |
5"/1.5mgon(3"/1.0mgon:NPL-362) |
Tilt sensor |
Type |
Dual-axis(NPL-362/352),
Single-axis(NPL-332) |
Method |
Liquid-electric detection |
Compensation range |
±3' |
Setting accuracy |
1" |
Level vial |
Plate level vial |
30"/2mm |
Circular level vial |
10'/2mm |
Optical plummet |
Magnification |
3x |
Focusing range |
0.5m/1.6 ft. to ∞ |
Display |
Graphic LCD (128 x 64
dot)
Both sides(NPL-362/352), Single side(NPL-332) |
Point memory |
10,000 records |
Dimensions (W x D x H) |
168 x 173 x 347mm/6.6
x 6.8 x 13.7 in. |
Weight (approx.) |
Main unit (with battery) |
5.5kg/12.1 lbs.(NPL-362/352),
5.3kg/11.7 lbs.(NPL-332) |
Battery |
0.4kg/0.9 lbs. |
Carrying case |
3.2kg/7.1 lbs |
On-board Ni-MH battery
BC-65 |
Operation time |
|
Continuous distance/angle
measurement |
Approx. 6.5 hours (Reflectorless
mode: 7.0 hours)*3 |
Distance/angle measurement
every 30 seconds |
Approx. 15 hours (Reflectorless
mode: 16 hours) |
Angle measurement |
Approx. 27 hours (Prism
and Reflectorless modes) |
Battery charger for BC-80/65 |
Approx. 3.0 hours for
full recharge |